2.0 Biosafety Level 2
                                 
                                 This class of laboratory is suitable for work involving agents of moderate potential
                                       hazard to personnel and the public. In addition to the characteristics of a Biosafety
                                       Level 1 facility, (a) laboratory personnel have specific training in handling pathogenic
                                       agents and are directed by competent scientists, (b) access to the laboratory is limited
                                       whenever work is being conducted, and (c) when some procedures are conducted in which
                                       infectious aerosols are created, they will be performed in biological safety cabinets
                                       or other physical containment equipment.
                                 
                                 Standard Microbiological Practices
                                 
                                 
                                    
                                    - Restrict access to the laboratory, at the discretion of the laboratory director, when
                                       experiments are in process.
 
                                    
                                    - Decontaminated work surfaces once each day and after any spill of viable material.
 
                                    
                                    - Decontaminate all contaminated liquid or solid wastes before disposal.
 
                                    
                                    - Always use mechanical pipetting devices; mouth pipetting is prohibited.
 
                                    
                                    - Eating, drinking, smoking and applying cosmetics are not permitted in the work area.
                                       Food can only be stored in cabinets or refrigerators specifically designated for that
                                       purpose. These must be located outside the work area.
 
                                    
                                    - Wash hands with a suitable disinfectant after handling viable materials and before
                                       leaving the laboratory.
 
                                    
                                    - Perform all procedures in a way that minimizes the creation of aerosols.
 
                                    
                                 
                                 Special Practices
                                 
                                 
                                    
                                    - Place all contaminated materials that will be decontaminated at a site away from the
                                       laboratory in a durable, leakproof container, which is closed before being removed
                                       from the laboratory.
 
                                    
                                    - Limit access to the laboratory for persons who are at increased risk of acquiring
                                       infection, or for whom infection might be unusually hazardous. The Laboratory Director
                                       has the final responsibility for determining who may enter or work in the laboratory.
 
                                    
                                    - Establish written policies and procedures whereby only persons who have been advised
                                       of the hazards and meet any specific entry requirements, e.g., special training or
                                       immunization, may enter the facility.
 
                                    
                                    - Post special provisions for entry, e.g., vaccination, a hazard warning sign incorporating
                                       the universal biohazard symbol on the door to the laboratory work area when the infectious
                                       agents is used in the laboratory . The warning sign identifies the infectious agent,
                                       lists the name of the Laboratory Director, laboratory supervisor and Department Head,
                                       and identifies the special requirements for entering the laboratory.
 
                                    
                                    - Ensure that an effective insect and rodent control program is in effect.
 
                                    
                                    - Wear laboratory coats, gowns, smocks or uniforms while in the laboratory. Before leaving
                                       the laboratory remove these garments and leave them in the laboratory. A clean coat
                                       may be worn over the potentially contaminated garments, but the outer garment must
                                       be considered contaminated upon removal.
 
                                    
                                    - Do not permit animals not involved in the research in the laboratory.
 
                                    
                                    - Use special care to avoid skin contamination with infectious materials. Wear gloves
                                       when handling infected animals and when skin contact with infectious materials is
                                       unavoidable.
 
                                    
                                    - Contaminate all wastes from laboratories and animal rooms before disposal.
 
                                    
                                    - Use hypodermic needles and syringes only for parenteral injection and aspiration of
                                       fluids from laboratory animals and diaphragm bottles. Use only needle-locking syringes
                                       or disposable syringe-needle units for the injection or aspiration of infectious fluids.
                                       Extreme caution should be used when handling needles and syringes to avoid autoinoculation
                                       and the generation of aerosols during use and disposal. Do not bend, cut, or replace
                                       needles in the sheath or guard or removed them the syringe following use. Place the
                                       needle and syringe promptly in a puncture-proof container and decontaminated, preferably
                                       by autoclaving, before discard or reuse.
 
                                    
                                    - Report spills and accidents that result in overt exposures to infectious agents immediately
                                       to the Laboratory Director. Medical evaluation, surveillance, and treatment will be
                                       provided as needed at no cost to the employee. Maintain written records of the incident,
                                       including a determination of the causes, any personnel exposed, and any actions that
                                       were taken.
 
                                    
                                    - Collect baseline serum samples for those individuals working with materials infectious
                                       to humans (including possibly infectious animals, animal tissues that have not been
                                       rendered safe, or derivative materials) and store. Additional serum samples will be
                                       taken at five-year intervals or after an overt exposure. Also, at a minimum, a medical
                                       history is required and it is recommended that the employees participate in a full
                                       Health Assurance Program.
 
                                    
                                    - Prepare a biosafety procedures. Advise personnel of special hazards that are required
                                       to become familiar with experimental practices and procedures, including all safety
                                       precautions.
 
                                    
                                 
                                 Containment Equipment
                                 
                                 
                                    
                                    - Use Class I or II biological safety cabinets or other appropriate personal protective
                                       or physical containment devices in the following situations:
 
                                    
                                    - When procedures with a high potential for creating infectious aerosols are conducted.
                                       These include but are not limited to centrifuging, grinding, blending, vigorous shaking
                                       or mixing, sonic disruption, pipetting, opening pressurized containers, inoculating
                                       animals intranasally, and harvesting infected tissues from animals, eggs, or plants.
 
                                    
                                    - When high concentrations or large volumes of infectious agents are used. Such materials
                                       may be centrifuged in the open laboratory if sealed heads or centrifuge safety cups
                                       are used and if they are opened only in a biological safety cabinet.
 
                                    
                                 
                                 Laboratory Facilities
                                 
                                 
                                    
                                    - Ensure that the laboratory is designed so that it is easily cleaned. Seamless or poured
                                       floor coverings are recommended. Epoxy paint is recommended for the walls. Junctures
                                       with the wall, floor, ceiling, and equipment should be rounded, with no corner seams.
                                       Laboratory furniture should incorporate as few sharp seams and cracks as possible.
                                       Penetrations in the floor should be sealed or capable of being sealed to aid decontamination.
 
                                    
                                    - Bench tops must be impervious to water and resistant to acids, alkalis, organic solvents,
                                       and moderate heat.
 
                                    
                                    - Spaces between benches, cabinets, and equipment must be accessible for cleaning.
 
                                    
                                    - Each laboratory contains a sink for hand washing.
 
                                    
                                    - Equip windows that can be opened with fly screens.
 
                                    
                                    - An autoclave should be available for decontaminating infectious wastes.